Fanuc 10t Parameter Manual -

Title

Entering Bit Parameters

The most critical parameters are the "Option" settings (9000 to 9139). These enable specific software features purchased with the machine. Important: Unlike standard parameters, these are often entered in Hexadecimal notation through the IPL (Initial Program Loader) screen.

  1. Backup First, Ask Questions Later: Output all current parameters to RS-232 (Punch). If you don't have a serial cable, take 40 high-resolution photos with your phone. I mean it.
  2. The "Option" Trap: Parameters 0000 to 0019 control hardware options (4th axis, Helical interpolation, Macro B). If you zero these out randomly, you turn a CNC into a manual lathe.
  3. Bit vs. Digit: The 10T uses a mix. Some parameters are Bit (0 or 1 per function). Some are Digit (0-9 per column). The manual shows circles with numbers inside. Read that legend, or you will set the wrong "bit 5" and crash the carriage.

Where to Download a PDF (Legally)

Step 2: Clearing the Memory

Backup, Versioning & Change Control

Have a question?

Ask us here!